XML Verifying the accuracy of dose distribution in Gamma Knife unit in presence of inhomogeneities using PAGAT polymer gel dosimeter and MC simulation Print

Author(s): T. Allahverdi Pourfallah *, M. Allahverdi, N. Riyahi Alam, M.R. Ay , M.H. Zahmatkesh
* - Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran , tallahvardi@razi.tums.ac.ir
Study Type: Original Research | Subject: Medical physics
Article abstract:
Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of Gamma Knife (GK) unit in homogeneous and inhomogeneous phantoms. Materials and Methods: A custom-built, 16 cm diameter spherical Plexiglas head phantom was. Inside the phantom, there was one cubic cutout for insertion of gel phantoms, and another cutout for inserting the inhomogeneities. The phantoms were scanned with a Siemens clinical 1.5 T MRI scanner. The multiple spin-echo sequence with 32 echoes was used for the MRI scans. Results: The results of measurement and simulation in homogeneous and inhomogeneous phantoms showed that the presence of inhomogeneities in head phantom could cause spatial uncertainty higher than ±2 mm and dose uncertainty higher than 7%. Conclusion: the presence of inhomogeneities could cause dose differences which were not in accordance with accuracy in treatment with GK radiosurgery. Moreover, the findings of Monte Carlo calculation revealed that the applied simulation code (EGSnrc) was a proper tool for evaluation of 3D dose distribution in GK unit. Iran. J. Radiat. Res., 2009; 7 (1): 49-56
KeywordsGamma knife, PAGAT gel dosimeter, EGSnrc, dose distribution.,
Full text [PDF 1394 kb]
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
Allahverdi Pourfallah T, Allahverdi M, Riyahi Alam N, Ay M, Zahmatkesh M. Verifying the accuracy of dose distribution in Gamma Knife unit in presence of inhomogeneities using PAGAT polymer gel dosimeter and MC simulation. International Journal of Radiation Research. 2009; 7 (1) :49-56
URL http://www.ijrr.com/browse.php?a_code=A-10-1-317&slc_lang=en&sid=1
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 7, Number 1 ( 6-2009)
International Journal of Radiation Research
Static site map - Persian site map - English site map - Created in 0.057 seconds with 633 queries by AWT YEKTAWEB 2.2.5.1