[Home ]    
Iranian Journal of Radiation Research
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 2, Number 4 (3-2005) ::
Back to browse issues page 2005, 2(4): 197-204
XML Alpha activity in Indian thermal springs Print

Author(s): K. Kant *, S.B. Upadhyay and S.K. Chakarvarti
Department of Physics, KL Mehta Dayanand College for Women, Faridabad, Haryana, India-121 001 kkant_67@rediffmail.com
Study Type: Original Research | Subject: Radiation Biology
Article abstract:

ABSTRACT

Background:

and soils with which it comes in contact. There is dual exposure from radon in water i.e. due to

inhalation of the radon released from the water into the ambient air and through ingestion when

water is used for drinking. As radon contaminated water adversely affects the health, it is

therefore fundamental from health and hygiene point of view to measure radium concentration

and radon exhalation rates in water.

Dissolved radon is contained in natural water due to primordial uranium in rocks

Materials and Methods

radium concentration and radon exhalation rate in water samples collected from various thermal

springs. The alpha tracks registered were counted by optical microscope at suitable magnification

and converted into radium concentration and subsequently radon exhalation rates were measured.

: LR-115, Type- II plastic track detectors were used to measure the

Results:

m

varied from 5.65 Bq l

exhalation rates varied from 2.37 mBq kg

± 0.36 mBq kg

The radon concentration emanated from water samples (air borne) varied from 84 Bq-3 to 827 Bq m-3 with an average of 429 ± 12.72 Bqm-3 and the dissolved radon concentration-1 to 55.66 Bq l-1 with an average of 28.88± 0.85 Bq l-1. The radon mass-1 hr-1 to 23.39 mBq kg-1 hr-1 with an average of 12.14-1 hr-1 and surface exhalation rates from 52.34 mBq m-2 hr-1 to 515.29 mBq m-2 hr-1

with an average of 267.36 ± 7.93 from different thermal spring water samples.

concentration varied from 0.30 Bq l

 The radium-1 to 2.93 Bq l-1 with an average of 1.52 ± 0.045 Bq l-1.

Conclusion:

drinking, is safe as far as radium concentration is concerned with the exception of a few isolated

thermal spring sources.

Results indicate that the thermal spring water, which is also being used forIran. J. Radiat. Res., 2005; 2 (4): 197-204
KeywordsSSNTDs, health, thermal spring, radon, Radium,
Full text [PDF 233 kb]
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
K. Kant , S.B. Upadhyay , S.K. Chakarvarti , Alpha activity in Indian thermal springs Iranian Journal of Radiation Research, 2005; 2 (4) :197-204
URL http://www.ijrr.com/browse.php?a_code=A-10-1-86&slc_lang=en&sid=1
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 2, Number 4 ( 3-2005)
Iranian Journal of Radiation Research
Static site map - Persian site map - English site map - Created in 0.084 seconds with 582 queries by AWT YEKTAWEB 2.0.6.5