[Home ]    
Iranian Journal of Radiation Research
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 1, Number 4 (3-2004) ::
Back to browse issues page 2004, 1(4): 199-204
XML Patient dose in routine X-ray examinations in Yazd state Print

Author(s): F. Bouzarjomehri *
Health Physics Dept. Shahid Sadoghi Univ. of Medical Sciences, Yazd, Iran
Study Type: Original Research | Subject: Radiation Biology
Article abstract:

Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure.

Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs were measured by UNFORS dosimeter for five common types (12 projections) of x-ray procedures in standard man for the 18 public hospitals of Yazd province.

Results: The median, 3rd quartile, minimum, and maximum values of each ESEs distributions are reported. The 12 histograms are presented showing wide distribution of measured ESE in each examination. The survey results are compared with guide levels that reported by CRCPD or NRPB. The sum of ESEs measurements such as in skull, Th-spine and L-spine are projection out of the guide levels. One of reasons of the wide ESEs distribution is miss unique role in selection of techniques for the same procedure and same patient size by operators in each center and even for one x-ray machine.

Conclusion: The findings support the importance of the on-going quality assurance program to ensure doses are kept to a level consistence with optimum imaging quality. Iran . J. Radiat. Res., 2004; 1(4): 199-204

Keywordsmedical x-ray, patient dose, quality control,
Full text [PDF 95 kb]
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
F. Bouzarjomehri , Patient dose in routine X-ray examinations in Yazd state Iranian Journal of Radiation Research, 2004; 1 (4) :199-204
URL http://www.ijrr.com/browse.php?a_code=A-10-1-30&slc_lang=en&sid=1
Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 1, Number 4 ( 3-2004)
Iranian Journal of Radiation Research
Static site map - Persian site map - English site map - Created in 0.082 seconds with 575 queries by AWT YEKTAWEB 2.0.6.5