[Home ]    
Iranian Journal of Radiation Research
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 3, Number 1 (6-2005) ::
Back to browse issues page 2005, 3(1): 21-30
XML Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code) Print

Author(s): M.T. Bahreyni Toossi * and H. Zare
Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran m-t-bahreyni@mums.ac.ir
Study Type: Original Research | Subject: Medical physics
Article abstract:
 

ABSTRACT

Background: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.

Material and Methods: In this work we have made use of ORNL mathematical phantoms with few modifications which have been made. The source has been defined as a point source, emitting photons into a solid angle. The X-ray beam was shaped by a collimator to produce a rectangular field at the midline of the phantom.

Results: To validate the simulation executed in this study normalized organs doses to unit ESD for hermaphrodite phantom were computed. Our results were compared with corresponding values presented by NRPB. In general organs doses obtained by application of MCNP-4C (present study) and corresponding values presented in NRPB were in good agreement. For further evaluation of our phantom, the values acquired for organ and effective doses by MCNP-4C and ODS-60 were compared.

Conclusion: The technique we have developed is capable of estimating organ and effective doses with a better accuracy than dose values obtained by employment of NRPB and ODS-60 technique.

 

KeywordsOrgan dose, effective dose, diagnostic radiology, Monte Carlo, MCNP-4C,
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
M.T. Bahreyni Toossi , H. Zare , Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code) Iranian Journal of Radiation Research, 2005; 3 (1) :21-30
URL http://www.ijrr.com/browse.php?a_code=A-10-1-120&slc_lang=en&sid=1
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 3, Number 1 ( 6-2005)
Iranian Journal of Radiation Research
Static site map - Persian site map - English site map - Created in 0.084 seconds with 580 queries by AWT YEKTAWEB 2.0.6.5