[Home ]    
Iranian Journal of Radiation Research
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
:: Volume 3, Number 1 (6-2005) ::
Back to browse issues page 2005, 3(1): 11-16
XML Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range Print

Author(s): H. Pourbeigi *, A.S. Meigooni, H. Ghafourian, R.A. Koona and M.H. Zahmatkesh
Department of Nuclear Research Center, Atomic Energy Organization of Iran, Tehran, Iran hpour_ir@yahoo.com
Study Type: Original Research | Subject: Radiation Biology
Article abstract:

 

ABSTRACT

Backgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.

Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film technique. In this technique, single-, double-, and triple- layers of films were exposed to the doses ranging from 0.5 to 10 Gy using a Co-60 photon beam. Calibration curves for corresponding layers of films were obtained with a spectrophotometer using a 680nm wavelength.

Results: The results indicated that the sensitivities of double and triple layers were approximately 200% and 300%, respectively, higher than a single-layer film.  The impact of multilayer film arrangement on the energy dependence of the MD-55-2 Radiochromic film has also been examined using 100KVp, 80 KVp, and 6 MV X-ray beams. The results indicated an insignificant (within 5%) change in film responses with the beam energy.

Conclusion: Therefore, the multilayer technique enhances the Radiochromic film sensitivity and expands its application to the low dose range in field of brachytherapy source dosimetry. 

 

Keywords
Full text [PDF 1262 kb]
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
H. Pourbeigi , A.S. Meigooni , H. Ghafourian , R.A. Koona , M.H. Zahmatkesh , Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range Iranian Journal of Radiation Research, 2005; 3 (1) :11-16
URL http://www.ijrr.com/browse.php?a_code=A-10-1-111&slc_lang=en&sid=1
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 3, Number 1 ( 6-2005)
Iranian Journal of Radiation Research
Static site map - Persian site map - English site map - Created in 0.084 seconds with 586 queries by AWT YEKTAWEB 2.0.6.5